Warrior Fyreslide FZ Doors, full height frameless façade, Warrior operable FZ & Warrior fixed FZ also an array of fire rated glazing solutions in order to meet the standards of building in bushfire prone areas as per AS3959.
The Warrior glazed range provides fire protection to bush fire prone areas with a BAL-FZ rating. A minimum -/30/- solution is required for building in bush fire prone areas and must be tested to comply with AS3959. Smoke Control’s team has taken numerous design considerations when finaliasing this project such as; strong wind loads on a largely glazed façade which resulted in reinforced fire rated glazed fin pillars to provide enhanced stability in order to resist the highest of wind loads.